Multi-line 2 AGC Application Software series 3.x.
Du er ved at downloade Multi-line 2 AGC Application Software series 3.x.
You have chosen to download our software.
Whitin a few seconds, you will receive an e-mail containing a download link.
Having trouble using the software? Please contact support@deif.com.
Best regards,
DEIF A/S
The software is subject to copyright DEIF A/S
By following the above mentioned link and downloading the file you automatically accept DEIF A/S copyright and license agreement (EULA). The license agreement can be found on www.deif.com/software
This software applies to the following DEIF products:
Du er ved at downloade 3.66.1
The main changes implemented since the last version are as follows:
New features:
- Support of mainboard "uP 8 PCB".
- Support of CAN bus hardware "Option H8.2 HW v2" requires mainboard "uP 8 PCB".
- Support of CAN bus hardware "Option H5/H8.8 HW v2" requires mainboard "uP 8 PCB".
Corrections:
- Under AMF applications where a second mains fail occurs with at least one DG running, the remaining DGs are now started with a multi start.
- Under AMF applications where a second mains fail occurs with at least one DG running and power cap overrule enabled, the timer is now reset (started over again) when DGs are ready and synchronised.
- Start enable was required to be energised, if used, to activate the breakers - corrected.
- Genset could start when SEMI button was pushed and no start signal had been given (occurred only with Option V0108 German display only).
- Faulty situation where the AGC-3 could reboot unexpectedly has been prevented (occurred only with Option N).
- AGC Mains MB opens unwantedly - corrected.
- Parameter 3410 relay A setup corrected, so display shows correct value.
- When LTO is activated with no Sync to mains; a delay is added to ensure that multimains status has been evaluated, before it is determined if MB should open.
- After MTU has released a new software for the SMART CONNECT module, the alarm "AL Speed Demand Failure" was always present due to a change in timeout changed from ~40m[s] ==> ~10m[s].
- Multimains MB fail control of 'Start engine' selection now used in AMF sequences.
- AGC-3 could reboot after CAN protocol change, if there was active CAN communication on the CAN line during the protocol change.
- Ut13-If an LTO sequence was initiated while an auto switch was active, an MB could end up opening and closing in endless loop - corrected.
- Attempting to stop during idle at start would ramp the engine to full speed and keep it running, if the running detection speed was reached during idle run.
- GB could previously close onto a black busbar when another unit had GB position failure.
- Update of self-check functionality.
- MB was able to open even though it was excluded from the LTO sequence - corrected.
- In LTO, if the TB was tripped by the TB Trip fail class, the MB was not able to close in all situations - corrected.
Ver. | Dato | Description |
---|---|---|
3.66.1 |
16-03-2015 |
New features:
Corrections:
|
3.65.5 |
01-07-2014 |
|
3.65.4 |
13-03-2014 |
Changes:
Corrections:
|
3.65.3 |
01-11-2012 |
PM compatibility version 1.01.4. Includes version. 1.01.3. Corrections:
|
3.65.2 |
13-07-2012 |
Corrections:
|
3.65.0 |
06-06-2012 |
New features:
Corrections:
|
3.63.1 |
16-03-2012 |
|
3.63.0 |
22-02-2012 |
PM compatibility version 1.01.0. Includes versions: 1.00.0, 1.00.1, 1.00.2 & 1.00.3. New features:
Changes:
Corrections:
|
3.62.1 |
16-12-2011 |
PM compatibility version 1.00.2. Includes versions: 1.00.0, 1.00.1. Corrections:
|
3.62.0 |
08-11-2011 |
New features:
Changes:
|
3.61.1 |
21-06-2011 |
Changes:
Corrections:
|
3.60.0 |
06-06-2011 |
New features:
Changes:
Corrections:
|
3.61.0 |
06-06-2011 |
New features:
Changes:
Corrections:
|
3.50.7 |
08-02-2011 |
|
3.50.6 |
17-08-2010 |
|
3.50.5 |
29-06-2010 |
|
3.50.4 |
10-06-2010 |
|
3.50.3 |
21-05-2010 |
|
3.50.2 |
23-04-2010 |
|
3.50.1 |
24-03-2010 |
|
3.50.0 |
05-01-2010 |
|
3.41.2 |
02-10-2009 |
|
3.41.1 |
18-08-2009 |
|
3.32.1 |
18-02-2009 |
|
3.41.0 |
18-02-2009 |
|
3.32.0 |
18-12-2008 |
|
3.31.1 |
31-10-2008 |
|
3.31.0 |
03-10-2008 |
|
3.30.0 |
15-07-2008 |
G4 Power management option introduced General update of power management options (G4 and G5) to handle multiple mains and bus tie breakers H8 option (Beckhoff) introduced J1939 ADEC (H5 only) and CUMMINS protocol supported General update of J1939 Diagnostics handling |
3.20.2 |
22-02-2008 |
|
3.20.1 |
04-12-2007 |
Problem with zip file. AGC_appl_v3201.zip |
3.20.1 |
03-12-2007 |
|
3.20.0 |
20-09-2007 |
|
3.10.7 |
12-07-2007 |
|
3.10.6 |
11-06-2007 |
|
3.10.5 |
04-06-2007 |
TB handling updated. |
3.10.4 |
11-05-2007 |
|
3.10.3 |
01-05-2007 |
|
3.10.2 |
16-03-2007 |
|
3.10.1 |
19-02-2007 |
|
3.10.0 |
18-01-2007 |
|
3.01.1 |
24-11-2006 |
Updates made for BB voltage protections. |
3.01.0 |
25-10-2006 |
Version 3.01.0 Changes:
|
3.00.1 |
02-10-2006 |
Changes:Updates made in G5 CAN error handling. Read_me.txt included in zip file. |
De nyeste versioner sikrer fuld funktionalitet
Vi anbefaler altid, at du installerer de tilgængelige opdateringer for at få fuldt udbytte af dit DEIF-produkt.
Alle softwareopdateringer kan downloades når som helst fra www.deif.com ved at vælge "Software" og derefter "Software Download".
Hvis du har spørgsmål eller problemer med at finde den relevante software til dit produkt, er du velkommen til at ringe til DEIF A/S på +45 9614 9614 eller det relevante lokale DEIF-kontor. Alternativt er vi altid klar til at hjælpe dig, hvis du sender en e-mail til support@deif.com.