Applikationer
Løsninger
Cases
Teknologier
Sider
Nyheder
Subsegments
Multi-line 300 PPU 300 ver. 1.x.x.
Du er ved at downloade Multi-line 300 PPU 300 ver. 1.x.x.
Denne software gælder for følgende DEIF-produkter:
Du er ved at downloade 1.0.4.1
De vigtigste implementerede ændringer siden den sidste version er:
This software package consist of:
- Multi-line 300, PPU 300
- Bundled with DU 300 SW version 1.0.10.0
PPU 300
Corrections:
- BSP version 3.0.1.0 supported.
- Negative fixed power deload dit not work. Instead of ramping to zero, it increases load.
- AVR/GOV output selection failure alarm triggered after software upgrade.
DU 300
New features:
- Support for multiple menu levels.
- Display shows a pop-up window for the user before going into service mode.
- Informs the user about development of the software.
Changes:
- Support for PlantSupervision ver 1.0.5.0.
Corrections:
- IOM3.4: DO's are not shown on display and in PICUS.
- Display is not loading min. and max. from parameters when they are changed.
- Power derate temperature is not shown on DU until power cycle.
- When changing type, DU sometimes freezes until it restarts.
- DU300 reboot in view designer.
- Not able to close alarm pop-up.
- Alarm "trigger value" is not updated if the alarm is already in the alarm list.
- DU300 does not check versions for individual REST resources.
- View designer cannot add counters to counters template.
Ver. | Dato | Description |
---|---|---|
1.0.4.1 |
04-03-2019 |
This software package consist of:
PPU 300Corrections:
DU 300New features:
Changes:
Corrections:
|
1.0.4.1 |
19-11-2018 |
This software package consist of:
PPU 300Corrections:
DU 300
|
1.0.4.0 |
06-07-2018 |
This software package consist of:
PPU 300New features:
DU 300
|
1.0.3.0 |
20-04-2018 |
This software package consist of:
PPU 300New features:
Changes:
Corrections:
DU 300New features:
Changes:
Corrections:
|
1.0.2.0 |
29-09-2017 |
New features:
Changes:
|
1.0.1.0 |
25-08-2017 |
This software package consist of:
PPU 300 New features: 1 - 4 directional over-current alarms have been added to BTB (ANSI 67). 2 - 2 directional over-current alarms have been added to SC and SG (ANSI 67). 3 - Support of lamp test function. 4 - Support of controller identify function. 5 - Active regulator mode will be deactivated if a new is requested. 6 - Additional information regarding alarms, breaker-, busbar- and generator status made available on Modbus. 7 - Added "Critical process error"" alarm. 8 - Last DG will trip if no other feeders are closed in the plant. Changes: 1 - "Power supply" parameter menu renamed to "Hardware". 2 - "Network" parameter group moved to "Hardware" instead of "Utility". 3 - "Reset ratio" renamed to "Hysteresis" for protection alarms. 4 - General check that "Nominal settings" cannot be configured to 0. 5 - "Fixed power factor" renamed to "Fixed CosPhi". 6 - "Analog" renamed to "Analogue". 7 - "System not OK" alarm action is changed to "Warning". 8 - New ACM 3.1 software 4.0.1.4. 9 - New PCM 3.1 software 2.0.0.2. 10 - The others are version 1.0.3.0. 11 - "Directional over-current" alarm min. and max. set points have been extended to -300 % and 300 %. 12 - Only one regulator request is accepted if more have been received. 13 - It is possible to configure action on "System not OK" alarm. Corrections: 1 - Controller types SC, SG and BTB stop synchronising if measure feedback disappears. 2 – Regulator could freeze if regulators were used in custom logic. 3 - Regulator continued to regulate after feedback failure on GB. DU 300 New features: - Implemented first part of custom stylesheets - Curves have been added to parameters - Lamp test - Identify feature to communication screen - Units change on display Changes: - Navigation and editing in I/O input text is now possible from the keyboard - Default live data views updated - Edit line design has been updated - Updated counter screen to use states - Default text in keyboard will show resolution - Live data screens dynamic update (step 1) - REST version control improvement step 1 (A+B match) - REST version control improvement step 2 (new REST resource implementation) - Live data dial meter and vertical bar widgets improved - Production screen changed to versions screen, production data now visible in about screen - Added DNS possibility to communication screen - Added IPv6 address to communication screen - Live data using REST to build screen and widgets - Terminal values updated to only show allowed precision - Updated help screens Corrections: - Custom inhibit does no longer clear other inhibit flags - Placeholder text from previous screen does no longer influence logon screen - Handling of empty list in pair screen - Pair screen automatically keeps rescanning for controllers if previously connected to a controller - Elements in parameters are represented in the same order as in the base unit - Preparation of lists in the application improved - Removed dot key from keyboard when value is integer, or precision is zero - Network off pop-up did not show the first time the display lost connection - Do not allow user to press OK in empty pair list - Cardlist serial to be a string instead of integer - Display reboots after setting up AVR - No longer showing all functions when function groups is empty - Cleaned up warnings - Not able to enable/disable the alarm "Ethernet redundancy broken" |
1.0.0.3 |
12-04-2017 |
This software package consist of:
PPU 300
Corrections: DU 300 No changes |
1.0.0.2 |
14-03-2017 |
Corrections:
|
1.0.0.0 |
21-12-2016 |
PPU 300: Initial release DU 300 ver. 1.0.5.0: New features:
Changes:
Corrections:
|
De nyeste versioner sikrer fuld funktionalitet
Vi anbefaler altid, at du installerer de tilgængelige opdateringer for at få fuldt udbytte af dit DEIF-produkt.
Alle softwareopdateringer kan downloades når som helst fra www.deif.com ved at vælge "Software" og derefter "Software Download".
Hvis du har spørgsmål eller problemer med at finde den relevante software til dit produkt, er du velkommen til at ringe til DEIF A/S på +45 9614 9614 eller det relevante lokale DEIF-kontor. Alternativt er vi altid klar til at hjælpe dig, hvis du sender en e-mail til support@deif.com.