Multi-line 2 ASC Application Software series 4.x

Du er ved at downloade Multi-line 2 ASC Application Software series 4.x

You have chosen to download our software.

Whitin a few seconds, you will receive an e-mail containing a download link.

Having trouble using the software? Please contact support@deif.com. 

Best regards, 

DEIF A/S

The software is subject to copyright DEIF A/S
By following the above mentioned link and downloading the file you automatically accept DEIF A/S copyright and license agreement (EULA). The license agreement can be found on www.deif.com/software

This software applies to the following DEIF products:

Du er ved at downloade 4.18.0

The main changes implemented since the last version are as follows:

PM compatibility version 1.24.1

New features:

  • SinExcel PCS VSG (Droop) support.
  • Breaker feedbacks from Power meter using DEIF control available as M-Logic inputs.
  • New weather protocol for POA and BOM reading: Kipp & Zonen - RT1 Smart Rooftop Monitoring System.
  • Havells 80-136kW PV protocol added.
  • Battery only: ESB on sequence configuration menu 2350. Can be used for delaying breaker close based on timer and running status.
  • Solar only: Choice of POA+BOM or GHI+BOM added to Instant Pmax parameter.
  • Solar only: Multiplier for POA/GHI irradiance sensor input now possible using parameter 6305.

Changes:

  • Added inhibits for Ext comm 1 err (Parameter 7520).
  • Added delay timer for BMS comm err (Parameter 7690).

Corrections:

  • Generating and charging capacities on Narada BMS now scaled correctly.
  • The monitoring telegram for SMA Cluster Controller wasn't cycling through the Modbus addresses.
  • Alarm inhibits were not working on some alarms
  • ASC-4 battery now only initiates charging after unit is powered up if SOC is below configured limit.
  • Minor corrections to Ausar MAE and PowerCube BMS protocols.
Ver. Dato Description

4.18.0

20-09-2021

PM compatibility version 1.24.1

New features:

  • SinExcel PCS VSG (Droop) support.
  • Breaker feedbacks from Power meter using DEIF control available as M-Logic inputs.
  • New weather protocol for POA and BOM reading: Kipp & Zonen - RT1 Smart Rooftop Monitoring System.
  • Havells 80-136kW PV protocol added.
  • Battery only: ESB on sequence configuration menu 2350. Can be used for delaying breaker close based on timer and running status.
  • Solar only: Choice of POA+BOM or GHI+BOM added to Instant Pmax parameter.
  • Solar only: Multiplier for POA/GHI irradiance sensor input now possible using parameter 6305.

Changes:

  • Added inhibits for Ext comm 1 err (Parameter 7520).
  • Added delay timer for BMS comm err (Parameter 7690).

Corrections:

  • Generating and charging capacities on Narada BMS now scaled correctly.
  • The monitoring telegram for SMA Cluster Controller wasn't cycling through the Modbus addresses.
  • Alarm inhibits were not working on some alarms
  • ASC-4 battery now only initiates charging after unit is powered up if SOC is below configured limit.
  • Minor corrections to Ausar MAE and PowerCube BMS protocols.

4.17.1

16-07-2021

PM compatibility version 1.24.1.

Corrections:

1- Corrected that the EVVO PV protocol did not send control telegrams to control the active power of the inverter.

4.17.0

28-06-2021

PM compatibility version 1.24.1.

New features:

  • ABB SACE Emax 2 protocol (Power meter) is added.
  • Fallback timer for power limit on SunSpec (parameter 2810) is added.
  • DEIF Generic BESS protocol is added.
  • DEIF Generic can now be choosen as a stand-alone BMS protocol.
  • Pylontech PowerCube H1/H2 BMS protocol is added.
  • Phase direction can now be controlled from M-Logic.
  • BMS warning and shutdown alarm (parameters 7610 and 7620) are added.
  • Battery droop logic is added in parameter 2800. (Currently supported by DEIF generic only).
  • Ausar MAE v2 battery protocol is added.
  • Option T1 shortcircuit protection (parameters 2301, 2302, 2303 and 2311) is added.
  • Option T1 redundancy on ASC Battery is added, along with improvements for ASC PV redundancy.
  • CATL BMS protocol is added.
  • FIMER PVS980-58BC battery protocol is added.
  • Support for BMS write telegrams over Modbus is added.

Changes:

  • Added BB volt/freq OK, BB voltage OK, BB frequency OK, PV volt/freq OK, PV voltage OK and PV frequency to M-Logic events.

Corrections:

  • Corrected that Sunspec initialization sometimes fails if the inverter takes too long to set up.
  • When the ASC is a solar unit, it can no longer send negative P-ref set points to the inverter.
  • Corrected that emulation units were not able to start with PV/BESS protocol set to OFF.

4.16.0

08-04-2021

PM compatibility version 1.23.0.

New features:

  • Sungrow Logger 1000 protocol is added.
  • GroWatt PV inverter protocol is added.
  • ATESS Growatt BCU protocol is added.
  • Modbus master communication monitoring tool is added in menu 9080 and to the Input registers at address 53000.

Changes:

  • Improved Q-share and de-load of last online DG.
  • Improved the SunSpec identifying information shown in the display.
  • Listed PV/BESS/PCS/BMS in alphabetic order in the display and in the USW.

Corrections:

  • Corrected: Hybrid controller gets stuck on Sunspec initialization.
  • MB EXTERN TRIPPED warning text removed as the MB is not controlled by the ASC-4.

4.15.1

25-02-2021

PM compatibility version 1.22.0.

Corrections:

  • Derated nominal battery power was not taken into account when calculating charging references.

4.15.0

30-11-2020

PM compatibility version 1.22.0.

New features:

  • Support of the shared parameter for configurable amount of Fatal CAN error alarm.
  • Sinexcel PCS inverter is added.
  • Narada BMS is added.
  • Spinning reserve feature is added. 

4-14-2

29-10-2020

PM compatibility version 1.20.0

Corrections:

  • OEM-specific correction updated.

4.12.0

19-03-2020

PM compatibility version 1.16.0.

New features:

  •    ASC in Load Point.
  •    Parameter for selecting P and Q mode writing when using Sunspec generic. 
  •    Support of Enerflow Inverter.
  •    Support of Delta RPI 88H Inverter.
  •    Support of GPPS Inverter.
  •    Support of BMS.
  •    Support of LFP BMS.
  •    Support of Delta Ohm Weather station.
  •    Support of SMA Sunny Island Inverter.
  •    Support of Evvo Inverter.
  •    Support of Huawei SUN2000 50-60KTL Inverter.
  •    Support of Huawei SUN2000 100-125M0-M2 Inverter.

4.11.3

28-01-2020

PM compatibility version 1.16.0

Corrections:

  • Wrong index in new measurement area for updated Sungrow protocol.

4.11.2

24-01-2020

PM compatibility version 1.16.0

Corrections:

  • ALC power is now a part of the emulation calculation.
  • Sungrow protocol is updated to the newest protocol. 
  • SolidQ protocol is updated to go from 0-110 % range power.  

4.11.1

31-10-2019

PM compatibility version 1.16.0.

Corrections:

  • Sunspec generic protocol is now able to support PVS100/120.

4.11.0

11-12-2018

PM compatibility version 1.16.0

New features:

  • Support of KStar inverter. 
  • Weatherstation support added. 
  • Support of PV and Mains power meter input in M-logic.
  • Support of Modbus based power readings from all DEIF controllers.
  • Support of ABB Trio 50 inverter. 
  • Support of GoodWe MT-series inverter. 
  • Support of Huawei SUN2000 55-60KTL inverter.
  • Support of Huawei SUN2000 90-105KTL inverter.
  • Support of APS PMU-100 energy meter.

Corrections:

  • Ginlong Solis protocol corrected.
  • Spinning reserve is now using the actual production. 

 

4.10.1

16-04-2018

Corrections:

  • Menu 2150, "Phase Sequence Error" was missing at ASC Solar.

4.10.0

20-03-2018

PM compatibility version 1.16.0

New features:

  • Battery variant
  • Support of SolarEdge inverter
  • Support of Tesla PowerPack inverter 
  • Support of Qinous inverter
  • Support of Vacon8000 inverter
  • Support of Chint 50/60 kW inverter 
  • Support of Chint 14/36 kW inverter 
  • Support of SolidQ 50 inverter
  • Support of SolidQ 60 inverter
  • Support of 16 ASCs, in ID range 25-40
       

Corrections:

  • Power management total power and reactive power readings in Modbus always displayed 0.

4.05.2

12-01-2018

Corrections:

  • Schneider iEM3000 protocol corrected.

4.05.1

02-01-2018

PM compatibility version 1.15.0

Corrections:
1- Fail classes initialised to "Shutdown" unintendedly.

 

4.05.0

30-11-2017

PM compatibility version 1.15.0

New features:

  • Support of 16 mains energy meter.
  • Support of Socomec Multis L40 energy meter.
  • Support of EDS MMT3(5A) energy meter.  
  • Support of Gossen mavalog energy meter.
  • Support of EDMI energy meter.
  • Support of calculated PF and kVA based on energy meter data. 
  • Support of Reuniwatt SkyInSight.
  • Support of Ginlong Solis inverter.

Corrections:

  • The ASC will not try to close after it is tripped due to under-voltage coil.

Changes:

  • Socomec Multis L40 changed to Socomec Diris a40. 
  • Generic SunSpec protocol updated. Unknown maker specific models no longer interpreted by the ASC as SunSpec map being incompatible.

 

4.04.0

05-10-2017

PM compatibility version 1.15.0

New features:

1- Support of HiQ inverter.
2- Support of IngeTeam inverter.
3- Support of Schneider PM5560 energy meter.
4- Support of Socomec Multis L40 energy meter.

4.03.1

09-05-2017

PM compatibility version 1.15.0

Corrections:

  • Correction to “Re-initialisation of PV inverter protocol made robust”.
  • PV Monitoring functionality malfunctioning in SunSpec protocol.

4.03.0

03-04-2017

Version 4.03.0
PM compatibility version 1.15.0

New features:

  • Support of short-term weather forecast system, SteadyEye, from SteadySun.

Changes:

  • "SMA SunSpec" protocol selection text changed to "SMA SunSpec v2.82". 

Corrections:

  • Re-initialisation of PV inverter protocol made robust.
  • PV curtailment "Yearly" counter displayed garbage.

 

4.02.0

21-12-2016

PM compatibility version 1.15.0

New features:

  • Support of Modbus-based power meters.
  • Support of DG and mains power readings via DEIF open protocol.
  • Support of GB/MB breaker feedbacks via M-Logic.
  • Support of INVT BG series inverter.
  • Mains kWh counters added.

Changes:

  • Option M4 made optional

Corrections:

  • Delta RPI interface corrected.
  • PV monitoring data could not be read via service port or H2.
  • MBON status not working in M-Logic.
  • Minimum genset load could not be accessed if Option G5 is not present.
  • Minimum genset load setting control from M-Logic did not work

De nyeste versioner sikrer fuld funktionalitet

Vi anbefaler altid, at du installerer de tilgængelige opdateringer for at få fuldt udbytte af dit DEIF-produkt.

Alle softwareopdateringer kan downloades når som helst fra www.deif.com ved at vælge "Software" og derefter "Software Download".

Hvis du har spørgsmål eller problemer med at finde den relevante software til dit produkt, er du velkommen til at ringe til DEIF A/S på +45 9614 9614 eller det relevante lokale DEIF-kontor. Alternativt er vi altid klar til at hjælpe dig, hvis du sender en e-mail til support@deif.com.