Multi-line 2 ASC Application Software series 4.x
Du er ved at downloade Multi-line 2 ASC Application Software series 4.x
You have chosen to download our software.
Whitin a few seconds, you will receive an e-mail containing a download link.
Having trouble using the software? Please contact support@deif.com.
Best regards,
DEIF A/S
The software is subject to copyright DEIF A/S
By following the above mentioned link and downloading the file you automatically accept DEIF A/S copyright and license agreement (EULA). The license agreement can be found on www.deif.com/software
This software applies to the following DEIF products:
- ASC-4 Battery - Automatic Sustainable Controller
- ASC-4 Solar - Automatic sustainable controller
- ASC-4 Battery Standalone - Automatic sustainable controller
Du er ved at downloade 4.22.0
The main changes implemented since the last version are as follows:
PM compatibility version 1.25.0
New features:
- The ASC4-Battery can now control if ext. DGs should be started or stopped based on system load or SOC through a dry contactor output.
- When the battery acts as a power source an optimal DG load can now be set through parameter 8014-8016, which the ASC will try to keep the DGs at.
- M-Logic commands for enabling and disabling the charge parameters added along with M-Logic feedbacks.
- Support for LS PowerBRiC ESS protocol added.
- Support for EOS Energy Block BMS protocol added.
- The ASC4-Battery can now limit the mains charging setpoint, so the peak shaving setpoint is not exceeded by enabling parameter 8024.
- The ASC4-Battery can now change the voltage reference to be based on the busbar measurement instead of the nominal voltage, when a mains is connected to the busbar using parameter 2661.
Changes:
- Sungrow LC100 Utility LFP BCU protocol now supports running in VSG-mode, when droop is enabled within the ASC.
- Sungrow STxxxCP50-HV BCU protocol updated for the latest VSG control scheme from Sungrow.
- TRUMPF TruConvert AC/DC ESS protocol updated to always acknowledge alarms and set the communication timeout to be 60s.
- Register address for SOC value from CellCheck CM BMS protocol updated.
- The voltage and frequency reference sent during synchronization of ESB will now always be based on the average busbar measurement of all three phases. As long they are within the set acceptable limit.
Corrections:
- New autostart conditions have been added for the ASC4 battery, so the ESS will have an autostart-signal when running in off-grid scenarios and is gridforming.
- When the ASC4 is in auto mode and an ESB close failure occurs, the inverter will only be stopped if the fail class of 2170 is set to be shutdown.
Ver. | Dato | Description |
---|---|---|
4.22.0 |
03-05-2022 |
PM compatibility version 1.25.0 New features:
Changes:
Corrections:
|
4.21.0 |
18-02-2022 |
PM compatibility version 1.25.0 New features: Changes: |
4.20.0 |
09-12-2021 |
PM compatibility version 1.24.2 New features:1- Sungrow LC100 BCU protocol added. Changes:1- Renamed "Ginlong Solis" PV protocol to "Solis (Ginlong)". |
4.19.0 |
22-11-2021 |
PM compatibility version 1.24.2 New features:
Changes:
Corrections:
|
4.18.0 |
20-09-2021 |
PM compatibility version 1.24.1 New features:
Changes:
Corrections:
|
4.17.1 |
16-07-2021 |
PM compatibility version 1.24.1. Corrections:1- Corrected that the EVVO PV protocol did not send control telegrams to control the active power of the inverter. |
4.17.0 |
28-06-2021 |
PM compatibility version 1.24.1. New features:
Changes:
Corrections:
|
4.16.0 |
08-04-2021 |
PM compatibility version 1.23.0. New features:
Changes:
Corrections:
|
4.15.1 |
25-02-2021 |
PM compatibility version 1.22.0. Corrections:
|
4.15.0 |
30-11-2020 |
PM compatibility version 1.22.0. New features:
|
4-14-2 |
29-10-2020 |
PM compatibility version 1.20.0 Corrections:
|
4.12.0 |
19-03-2020 |
PM compatibility version 1.16.0. New features:
|
4.11.3 |
28-01-2020 |
PM compatibility version 1.16.0 Corrections:
|
4.11.2 |
24-01-2020 |
PM compatibility version 1.16.0 Corrections:
|
4.11.1 |
31-10-2019 |
PM compatibility version 1.16.0. Corrections:
|
4.11.0 |
11-12-2018 |
PM compatibility version 1.16.0 New features:
Corrections:
|
4.10.1 |
16-04-2018 |
Corrections:
|
4.10.0 |
20-03-2018 |
PM compatibility version 1.16.0 New features:
Corrections:
|
4.05.2 |
12-01-2018 |
Corrections:
|
4.05.1 |
02-01-2018 |
PM compatibility version 1.15.0
|
4.05.0 |
30-11-2017 |
PM compatibility version 1.15.0 New features:
Corrections:
Changes:
|
4.04.0 |
05-10-2017 |
PM compatibility version 1.15.0 New features:1- Support of HiQ inverter. |
4.03.1 |
09-05-2017 |
PM compatibility version 1.15.0 Corrections:
|
4.03.0 |
03-04-2017 |
Version 4.03.0 New features:
Changes:
Corrections:
|
4.02.0 |
21-12-2016 |
PM compatibility version 1.15.0 New features:
Changes:
Corrections:
|
De nyeste versioner sikrer fuld funktionalitet
Vi anbefaler altid, at du installerer de tilgængelige opdateringer for at få fuldt udbytte af dit DEIF-produkt.
Alle softwareopdateringer kan downloades når som helst fra www.deif.com ved at vælge "Software" og derefter "Software Download".
Hvis du har spørgsmål eller problemer med at finde den relevante software til dit produkt, er du velkommen til at ringe til DEIF A/S på +45 9614 9614 eller det relevante lokale DEIF-kontor. Alternativt er vi altid klar til at hjælpe dig, hvis du sender en e-mail til support@deif.com.