Multi-line 2 ASC Application Software series 4.x

Denne software gælder for følgende DEIF-produkter:

Du er ved at downloade 4.11.0

De vigtigste implementerede ændringer siden den sidste version er:

PM compatibility version 1.16.0

New features:

  • Support of KStar inverter. 
  • Weatherstation support added. 
  • Support of PV and Mains power meter input in M-logic.
  • Support of Modbus based power readings from all DEIF controllers.
  • Support of ABB Trio 50 inverter. 
  • Support of GoodWe MT-series inverter. 
  • Support of Huawei SUN2000 55-60KTL inverter.
  • Support of Huawei SUN2000 90-105KTL inverter.
  • Support of APS PMU-100 energy meter.

Corrections:

  • Ginlong Solis protocol corrected.
  • Spinning reserve is now using the actual production. 

 

Ver. Dato Description

4.11.0

11-12-2018

PM compatibility version 1.16.0

New features:

  • Support of KStar inverter. 
  • Weatherstation support added. 
  • Support of PV and Mains power meter input in M-logic.
  • Support of Modbus based power readings from all DEIF controllers.
  • Support of ABB Trio 50 inverter. 
  • Support of GoodWe MT-series inverter. 
  • Support of Huawei SUN2000 55-60KTL inverter.
  • Support of Huawei SUN2000 90-105KTL inverter.
  • Support of APS PMU-100 energy meter.

Corrections:

  • Ginlong Solis protocol corrected.
  • Spinning reserve is now using the actual production. 

 

4.10.1

16-04-2018

Corrections:

  • Menu 2150, "Phase Sequence Error" was missing at ASC Solar.

4.10.0

20-03-2018

PM compatibility version 1.16.0

New features:

  • Battery variant
  • Support of SolarEdge inverter
  • Support of Tesla PowerPack inverter 
  • Support of Qinous inverter
  • Support of Vacon8000 inverter
  • Support of Chint 50/60 kW inverter 
  • Support of Chint 14/36 kW inverter 
  • Support of SolidQ 50 inverter
  • Support of SolidQ 60 inverter
  • Support of 16 ASCs, in ID range 25-40
       

Corrections:

  • Power management total power and reactive power readings in Modbus always displayed 0.
 

4.05.2

12-01-2018

Corrections:

  • Schneider iEM3000 protocol corrected.

4.05.1

02-01-2018

PM compatibility version 1.15.0

Corrections:
1- Fail classes initialised to "Shutdown" unintendedly.

 

4.05.0

30-11-2017

PM compatibility version 1.15.0

New features:

  • Support of 16 mains energy meter.
  • Support of Socomec Multis L40 energy meter.
  • Support of EDS MMT3(5A) energy meter.  
  • Support of Gossen mavalog energy meter.
  • Support of EDMI energy meter.
  • Support of calculated PF and kVA based on energy meter data. 
  • Support of Reuniwatt SkyInSight.
  • Support of Ginlong Solis inverter.

Corrections:

  • The ASC will not try to close after it is tripped due to under-voltage coil.

Changes:

  • Socomec Multis L40 changed to Socomec Diris a40. 
  • Generic SunSpec protocol updated. Unknown maker specific models no longer interpreted by the ASC as SunSpec map being incompatible.

 

4.04.0

05-10-2017

PM compatibility version 1.15.0

New features:

1- Support of HiQ inverter.
2- Support of IngeTeam inverter.
3- Support of Schneider PM5560 energy meter.
4- Support of Socomec Multis L40 energy meter.

4.03.1

09-05-2017

PM compatibility version 1.15.0

Corrections:

  • Correction to “Re-initialisation of PV inverter protocol made robust”.
  • PV Monitoring functionality malfunctioning in SunSpec protocol.

4.03.0

03-04-2017

Version 4.03.0
PM compatibility version 1.15.0

New features:

  • Support of short-term weather forecast system, SteadyEye, from SteadySun.

Changes:

  • "SMA SunSpec" protocol selection text changed to "SMA SunSpec v2.82". 

Corrections:

  • Re-initialisation of PV inverter protocol made robust.
  • PV curtailment "Yearly" counter displayed garbage.
 

4.02.0

21-12-2016

PM compatibility version 1.15.0

New features:

  • Support of Modbus-based power meters.
  • Support of DG and mains power readings via DEIF open protocol.
  • Support of GB/MB breaker feedbacks via M-Logic.
  • Support of INVT BG series inverter.
  • Mains kWh counters added.

Changes:

  • Option M4 made optional

Corrections:

  • Delta RPI interface corrected.
  • PV monitoring data could not be read via service port or H2.
  • MBON status not working in M-Logic.
  • Minimum genset load could not be accessed if Option G5 is not present.
  • Minimum genset load setting control from M-Logic did not work

De nyeste versioner sikrer fuld funktionalitet

Vi anbefaler altid, at du installerer de tilgængelige opdateringer for at få fuldt udbytte af dit DEIF-produkt.

Alle softwareopdateringer kan downloades når som helst fra www.deif.com ved at vælge "Software" og derefter "Software Download".

Hvis du har spørgsmål eller problemer med at finde den relevante software til dit produkt, er du velkommen til at ringe til DEIF A/S på +45 9614 9614 eller det relevante lokale DEIF-kontor. Alternativt er vi altid klar til at hjælpe dig, hvis du sender en e-mail til support@deif.com.