This software applies to the following DEIF products:

Du er ved at downloade 4.12.0

The main changes implemented since the last version are as follows:

PM compatibility version 1.21.0.

New features:

  •    Configurable amount of units for triggering Fatal CAN Error alarm is added in menu 8800.

Changes:

  •    Support of ASC-4 redundancy.

Corrections:

  •    Corrected that selection of ‘Number of PMS units’ and ‘PMS CAN baud rate’ previously would only work with default settings. and an issue with redundancy.
Ver. Dato Description

4.12.0

26-11-2020

PM compatibility version 1.21.0.

New features:

  •    Configurable amount of units for triggering Fatal CAN Error alarm is added in menu 8800.

Changes:

  •    Support of ASC-4 redundancy.

Corrections:

  •    Corrected that selection of ‘Number of PMS units’ and ‘PMS CAN baud rate’ previously would only work with default settings. and an issue with redundancy.

4.11.0

13-02-2020

PM compatibility version 1.16.0
Includes version 1.15.0

New features:

  •    Now possible to open and close LG's while position failure is present.
  •    Block LG fail classes added
          • Position failure alarms set default to LG Block fail class.

Corrections:

  •    Corrected ALC Breaker Feedback Emulation.

4.10.1

10-01-2020

PM compatibility version 1.16.0

Corrections:

  •    Horn relay now working
  •    M-Logic PMS flags for GB/MB closed now working 
  •    LG(load group) pos. fail alarm now possible when LG is disabled

4.10.0

12-12-2019

PM compatibility version 1.16.0

Features:

  •    32 DG/Mains support
          • Support of 32 DG's in ID range 1-32 (AGC-4/200, version 4.65.0 required).
          • Support of 32 Mains in ID range 1-32 (AGC-4/200, version 4.65.0 required).
          • Support of 16 ASC's in ID range 25-40 (ASC-4, version 4.06.0 required).
          • Support of  8 ALC's in ID range 25-40.
  •    Support of ASC PV and Battery.
  •    Heavy Consumer logic added.
  •    Flip/Flops added to M-logic.

Changes:

  •    Disconnect Load can now be set to 200 % and 999 sec.

Corrections:

  •    Corrected: Tripped open relay hanging on redundant unit.
  •    Corrected: LG's are not opened in AUTO mode when disabled.
  •    Corrected: Digital input alarms are not activated by input.

4.00.1

29-01-2018

Corrections:

  • In some instances, all fail classes were initialised to "Shutdown" unintentionally.

4.00.0

30-10-2017

PM compatibility version 1.15.0
  
Features:
1- Includable in Power Management application type "Standard" together with AGC-4 and AGC 200.
a) Up to 16 gensets.
  b) Up to 16 mains.
c) Up to 8 BTBs/ALCs in plants.
d) Spinning reserve support.
2- Able to close and open breakers according to available power from DG. 
3- Able to place the ALC in mains load point.  

De nyeste versioner sikrer fuld funktionalitet

Vi anbefaler altid, at du installerer de tilgængelige opdateringer for at få fuldt udbytte af dit DEIF-produkt.

Alle softwareopdateringer kan downloades når som helst fra www.deif.com ved at vælge "Software" og derefter "Software Download".

Hvis du har spørgsmål eller problemer med at finde den relevante software til dit produkt, er du velkommen til at ringe til DEIF A/S på +45 9614 9614 eller det relevante lokale DEIF-kontor. Alternativt er vi altid klar til at hjælpe dig, hvis du sender en e-mail til support@deif.com.